Project

General

Profile

Actions

Bug #12159

closed

truss psflags printing is broken

Added by John Levon over 3 years ago. Updated over 3 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Start date:
Due date:
% Done:

100%

Estimated time:
Difficulty:
Medium
Tags:
Gerrit CR:
External Bug:

Description

after 12126, we always add a number suffix in prt_psflags, e.g. PROC_SEC_ASLR|0

Actions #1

Updated by John Levon over 3 years ago

Testing: Verified truss output looks OK, and secflags_truss now passes again.

Actions #2

Updated by Electric Monk over 3 years ago

  • Status changed from New to Closed
  • % Done changed from 0 to 100

git commit b377984a15f854afd6ce777dfe332bac906ff7ba

commit  b377984a15f854afd6ce777dfe332bac906ff7ba
Author: John Levon <john.levon@joyent.com>
Date:   2020-01-07T17:05:50.000Z

    12159 truss psflags printing is broken
    Reviewed by: Toomas Soome <tsoome@me.com>
    Approved by: Robert Mustacchi <rm@fingolfin.org>

Actions

Also available in: Atom PDF