Project

General

Profile

Actions

Bug #12955

closed

coretemp had the wrong granularity

Added by Robert Mustacchi about 1 year ago. Updated about 1 year ago.

Status:
Closed
Priority:
Normal
Category:
driver - device drivers
Start date:
Due date:
% Done:

100%

Estimated time:
Difficulty:
Medium
Tags:
Gerrit CR:

Description

While working on #12954, I realized that past me had made a mistake that turned out not to matter too much. The ksensor framework has a notion of the granularity, being the units of the actual measurement and how to transform it into degrees, and the precision, being a +/- range that the sensor is accurate within. Hardware provides a register one can read which describes the actual precision which it calls the 'resolution'. In the original implementation in #11184 this was used as the 'granularity'. On almost all systems, this is one degree, so there was no impact from this and why when comparing the initial readings to the ipmi values on servers we didn't see any discrepancies. We should fix this while we're going through and doing #12954.


Related issues

Related to illumos gate - Feature #12954: Rewrite coretemp to use the ksensor frameworkClosedRobert Mustacchi

Actions
Actions