Actions
Bug #4508
closedflowadm not working as documented, or documentation incorrect
Start date:
2014-01-18
Due date:
% Done:
100%
Estimated time:
Difficulty:
Tags:
needs-triage
Gerrit CR:
External Bug:
Description
From the SYNOPSIS of flowadm man page -
flowadm show-flow [-pP] [-S] [-s [-i interval]] [-l link] [-o field[,...]] [flow]
From the explanation of show-flow sub-command -
-s, --statistics Displays flow statistics. -i interval, --interval=interval Used with the -s option to specify an interval, in seconds, at which statistics should be displayed. If this option is not specified, statistics are displayed once.
Observed behaviour -
shruti@justforkix:~$ flowadm show-flow -s -i 1 testflow
flowadm: unrecognized option '-s'
shruti@justforkix:~$ flowadm show-flow -s testflow
flowadm: unrecognized option '-s'
Updated by Peter Tribble almost 4 years ago
- Category set to manpage - manual pages
- Assignee set to Peter Tribble
Similar to #7210, these usage stats were moved to flowstat, so should be removed from the man page here.
Updated by Electric Monk over 3 years ago
- Status changed from New to Closed
- % Done changed from 0 to 100
git commit 9dc2843d4266243e87f5d9de7a90b86235a6da08
commit 9dc2843d4266243e87f5d9de7a90b86235a6da08 Author: Peter Tribble <peter.tribble@gmail.com> Date: 2020-03-04T07:27:56.000Z 4508 flowadm not working as documented, or documentation incorrect 4538 flowadm man page does not list lport and rport as output fields for show-flow 7210 flowadm does not have show-usage command described in the manual page Reviewed by: Andy Fiddaman <andy@omniosce.org> Approved by: Robert Mustacchi <rm@fingolfin.org>