Bug #7822
Faults for fans that don't exist
Start date:
2017-01-30
Due date:
% Done:
100%
Estimated time:
Difficulty:
Bite-size
Tags:
Gerrit CR:
Description
Some JBODs report fans that are not attached in their SES inventory, e.g. some SuperMicro.
We need to rely on SES_PROP_FAIL instead of SES_PROP_OFF to report the fault.
--------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY --------------- ------------------------------------ -------------- --------- Jan 30 06:25:23 05b3efb0-41bc-c163-88a7-f099050d3ce6 SENSOR-8000-26 Minor Host : antares Platform : VMware-Virtual-Platform Chassis_id : VMware-56-4d-9d-6a-61-c6-b5-16-04-4d-95-7f-9d-81-77-ef Product_sn : Fault class : fault.fan.failed Problem in : "JBOD_Fan1" (hc://:product-id=LSI-SAS2X36:server-id=:chassis-id=5003048000339b3f/ses-enclosure=0/fan=3) faulted but still in service FRU : "JBOD_Fan1" (hc://:product-id=LSI-SAS2X36:server-id=:chassis-id=5003048000339b3f/ses-enclosure=0/fan=3) faulty Description : External sensors indicate that a fan is no longer operating correctly. Refer to http://illumos.org/msg/SENSOR-8000-26 for more information. Response : None. Impact : The enclosure may be getting inadequate cooling. If the problem persists, the components may overheat and the enclosure may shutdown. Action : Check the fan to see if the fan has lost power or there is a physical obstruction. Replace the fan if the internal mechanism has failed. --------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY --------------- ------------------------------------ -------------- --------- Jan 30 06:25:23 abe71118-cd13-c59f-c9be-e8b6834d00d1 SENSOR-8000-26 Minor Host : antares Platform : VMware-Virtual-Platform Chassis_id : VMware-56-4d-9d-6a-61-c6-b5-16-04-4d-95-7f-9d-81-77-ef Product_sn : Fault class : fault.fan.failed Problem in : "JBOD_Fan2" (hc://:product-id=LSI-SAS2X36:server-id=:chassis-id=5003048000339b3f/ses-enclosure=0/fan=4) faulted but still in service FRU : "JBOD_Fan2" (hc://:product-id=LSI-SAS2X36:server-id=:chassis-id=5003048000339b3f/ses-enclosure=0/fan=4) faulty Description : External sensors indicate that a fan is no longer operating correctly. Refer to http://illumos.org/msg/SENSOR-8000-26 for more information. Response : None. Impact : The enclosure may be getting inadequate cooling. If the problem persists, the components may overheat and the enclosure may shutdown. Action : Check the fan to see if the fan has lost power or there is a physical obstruction. Replace the fan if the internal mechanism has failed.
Updated by Electric Monk about 4 years ago
- Status changed from In Progress to Closed
- % Done changed from 50 to 100
git commit db7d70016bd48ccf97e39289929cbb412cf27ba2
commit db7d70016bd48ccf97e39289929cbb412cf27ba2 Author: Yuri Pankov <yuri.pankov@nexenta.com> Date: 2017-02-13T19:29:50.000Z 7822 Faults for fans that don't exist Reviewed by: Jeffry Molanus <jeffry.molanus@nexenta.com> Reviewed by: Jason King <jason.brian.king@gmail.com> Reviewed by: Robert Mustacchi <rm@joyent.com> Approved by: Dan McDonald <danmcd@omniti.com>