Project

General

Profile

Bug #7822

Faults for fans that don't exist

Added by Yuri Pankov about 4 years ago. Updated about 4 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
lib - userland libraries
Start date:
2017-01-30
Due date:
% Done:

100%

Estimated time:
Difficulty:
Bite-size
Tags:
Gerrit CR:

Description

Some JBODs report fans that are not attached in their SES inventory, e.g. some SuperMicro.

We need to rely on SES_PROP_FAIL instead of SES_PROP_OFF to report the fault.

--------------- ------------------------------------  -------------- ---------
TIME            EVENT-ID                              MSG-ID         SEVERITY
--------------- ------------------------------------  -------------- ---------
Jan 30 06:25:23 05b3efb0-41bc-c163-88a7-f099050d3ce6  SENSOR-8000-26 Minor

Host        : antares
Platform    : VMware-Virtual-Platform   Chassis_id  : VMware-56-4d-9d-6a-61-c6-b5-16-04-4d-95-7f-9d-81-77-ef
Product_sn  :

Fault class : fault.fan.failed
Problem in  : "JBOD_Fan1" (hc://:product-id=LSI-SAS2X36:server-id=:chassis-id=5003048000339b3f/ses-enclosure=0/fan=3)
                  faulted but still in service
FRU         : "JBOD_Fan1" (hc://:product-id=LSI-SAS2X36:server-id=:chassis-id=5003048000339b3f/ses-enclosure=0/fan=3)
                  faulty

Description : External sensors indicate that a fan is no longer operating
              correctly.  Refer to http://illumos.org/msg/SENSOR-8000-26 for
              more information.

Response    : None.

Impact      : The enclosure may be getting inadequate cooling.  If the problem
              persists, the components may overheat and the enclosure may
              shutdown.

Action      : Check the fan to see if the fan has lost power or there is a
              physical obstruction.  Replace the fan if the internal mechanism
              has failed.

--------------- ------------------------------------  -------------- ---------
TIME            EVENT-ID                              MSG-ID         SEVERITY
--------------- ------------------------------------  -------------- ---------
Jan 30 06:25:23 abe71118-cd13-c59f-c9be-e8b6834d00d1  SENSOR-8000-26 Minor

Host        : antares
Platform    : VMware-Virtual-Platform   Chassis_id  : VMware-56-4d-9d-6a-61-c6-b5-16-04-4d-95-7f-9d-81-77-ef
Product_sn  :

Fault class : fault.fan.failed
Problem in  : "JBOD_Fan2" (hc://:product-id=LSI-SAS2X36:server-id=:chassis-id=5003048000339b3f/ses-enclosure=0/fan=4)
                  faulted but still in service
FRU         : "JBOD_Fan2" (hc://:product-id=LSI-SAS2X36:server-id=:chassis-id=5003048000339b3f/ses-enclosure=0/fan=4)
                  faulty

Description : External sensors indicate that a fan is no longer operating
              correctly.  Refer to http://illumos.org/msg/SENSOR-8000-26 for
              more information.

Response    : None.

Impact      : The enclosure may be getting inadequate cooling.  If the problem
              persists, the components may overheat and the enclosure may
              shutdown.

Action      : Check the fan to see if the fan has lost power or there is a
              physical obstruction.  Replace the fan if the internal mechanism
              has failed.
#1

Updated by Yuri Pankov about 4 years ago

  • Description updated (diff)
#2

Updated by Electric Monk about 4 years ago

  • Status changed from In Progress to Closed
  • % Done changed from 50 to 100

git commit db7d70016bd48ccf97e39289929cbb412cf27ba2

commit  db7d70016bd48ccf97e39289929cbb412cf27ba2
Author: Yuri Pankov <yuri.pankov@nexenta.com>
Date:   2017-02-13T19:29:50.000Z

    7822 Faults for fans that don't exist
    Reviewed by: Jeffry Molanus <jeffry.molanus@nexenta.com>
    Reviewed by: Jason King <jason.brian.king@gmail.com>
    Reviewed by: Robert Mustacchi <rm@joyent.com>
    Approved by: Dan McDonald <danmcd@omniti.com>

Also available in: Atom PDF